Underpressure blanketing
Purpose Below principal drawing of NEGATIV PRESSURE BLANKETING with INERTGAS for storage tanks, reactors, vessels and other volumes. Negativ pressure gas blanketing is used to hold a light underpressure in the tank. This prevents the escape of toxical or dangerous products.
|
Pression The two necessary negativ pressure are mostly adjusted and leaded, as exaple: . |
|
Capacity The flow-out volume determines the capacity of the depressure regulator, the flow-in volume determines the capacity of the depressire limiter. |
Function The ventilation sucks trough the open under pressure limiter the tank in a vacuum. Arriving at -10 mbar the under pressure limiter is closing by emptying the tank the vacuum is encreasing continuously. At a under pressure of -40 mbar the under pressure reducer begins ato feed nitrogen and holds the vacuum constant. |